1080 Total Organic Carbon (TOC) Analyzer

The 1080 Total Organic Carbon Analyzer uses high-temperature (680 ºC) catalytic combustion to oxidize and convert organic compounds present in aqueous samples to CO2 for measurement by a solid-state, non-dispersive infrared detector (SS-NDIR). Though high-temperature combustion TOC has been shown to be very effective for the analysis of samples that are of high molecular weight or contain substantial amounts of salt or difficult-to oxidize organics (e.g., humic acids), these types of samples are problematic for typical combustion TOC analyzers. Our patented technologies protect the catalyst, increase reliability, reduce maintenance and operating costs, and extend the life of the instrument.

Designed for Performance and Simplicity

The 1080 processes aqueous samples for analysis of the total organic carbon total inorganic carbon and non-purgeable organic carbon (NPOC) content. Supporting USEPA-approved methods, Standard Methods, ASTM, DIN/ISO/CEN, and EU Methods our 1080 can analyze up to 300 samples per 24-hour period, depending upon the protocol employed, in excess of 100,000 samples per year. Principal applications include wastewater, seawater, industrial process water, drinking water, groundwater, and cooling water.

The 1080 also employs a multi-step analysis technique to distinguish and quantify different forms of carbon present in sample matrices and determine organic content.

TIC concentration is determined by acidifying a sample to a pH less than 2. Carbonates and bicarbonates in the sample dissociate, forming CO2, which is measured by a solid-state non-dispersive infrared detector (SS-NDIR) and reported in mass and concentration values.

TIC-free samples are Pulse-Timed injected into the reactor to perform high temperature (680 ºC) combustion over a platinum catalyst. Organic compounds are oxidized and converted into CO2, which is then quantified by the SS-NDIR detector. The result is reported as the TOC content in both mass and concentration of carbon.

The 1080 Analyzer also supports many analytical approaches — TC/TIC/TOC/NPOC analysis techniques and standard measurements, as well as simultaneous determination of total bound nitrogen (TNb) using the optional TNb analysis module.

 

Features and Benefits

 

Solid-State Non-Dispersive Infrared Detector     Solid-State Non-Dispersive Infrared Detector (SS-NDIR)

Reduces interferences from other compounds for accurate and reproducible results.

Electronic Pressure Control for TOC Analysis    Electronic Pressure Control (EPC)

Utilized for critical flow adjustments.

Patented TOC Technology from OI Analytical   Patented Technology

Less maintenance and longer instrument life with both the Catalyst Guard® and the Smart Slide Injector® (which extends the life of o-rings)

Easy Accessibility for TOC Analysis    Easy Accessibility

Open architecture provides easy service access to critical components and reagents.

LIMS Connectivity for TOC Analysis   LIMS Connectivity

Measurement results can be easily transferred to Laboratory Information Management Systems.

Reduce Training Time with TOC Training materials    Video Tutorials

Reduce training time with quick access to OI Analytical knowledge base.

Intuitive Software for your TOC Analysis    Intuitive Software

Simple, icon-driven interface and user-friendly functionality.


With over 50 years of experience designing TOC analyzers, OI Analytical has developed the 1080 to give you the accurate results you need with a low cost of ownership and unprecedented ease of use. Engineered for unsurpassed reliability and simple operation, the Model 1080 Total Organic Carbon Analyzer handles even the most challenging applications with precision and ease.

Test Methods Supported

The high-temperature combustion technique has been approved and adopted in numerous regulatory compliance methods, standards, and norms for water quality testing.

USEPA 415.1 – Drinking Water

Standard Method 5310B – Wastewater, Ground & Surface Waters

USEPA 9060A – Wastewater, Ground & Surface Waters

USEPA-DBPR – Disinfection Byproduct Rule

ISO 8245 – Drinking Water & Wastewater

EN 1484 – Surface & Ground Water, Potable Water

ASTM D7573-09 – Water, Wastewater & Sea Water

 

 

Automation

The 1080 offers automatic sample acidification and sparging. The automatic dilution function reduces sample salinity, acidity, and alkalinity, significantly extending the dynamic range.

Priority Sample on the Fly & Increased Throughput

With intuitive software features, priority samples can be added at any time without interrupting the operation of the instrument. The Model 1088 Autosampler analyzes up to 88 samples unattended freeing the operator’s time for other projects.

Compact Design

The autosampler was designed to fit beneath the 1080, conserving bench space.

Intuitive Software

TOCView provides fully automated data collection, analysis, reporting, storage in a LIMS environment using logical, and easy-to-follow design. Create methods for the analysis, set up and prioritize samples, quickly monitor instrument parameters, perform routine checks, review results, and generate reports all from TOCView.

Optional Accessories

The 1080 can be equipped with a number of instrument options and automation accessories to improve sample throughput and productivity. Our 88-position Rotary Autosampler, which offers automated dilution, in-situ stirring, and 88 (40 mL) sample vials, can be positioned below the analyzer for convenient installation. The optional TNb Nitrogen detector allows the measurement of total bound (inorganic and organic) nitrogen (excluding N2) in aqueous samples in tandem with TOC analysis.

Teknik Özellikler

Method Compliance USEPA, CEN, USP, EUP, ASTM, ISO, DIN, STD
Furnace Temperature Adjustable, 680 ˚C in 1˚C increments – 720 ˚C for TNb
Measurement Range 50 ppb C – 2,000 ppm C
(multiple calibration ranges or dilution required)
Measuring time From 3 minutes
Oxidation technique High temperature catalytic oxidation, liquid samples
Options available TNb module, 88-position rotary autosampler
Method TC 680 ˚C with Platinum catalyst
Method TIC Acidification and sparging
Method TOC NPOC, combustion of TIC-free sample, TOC–TIC
Reproducibility 3.0%
Accuracy +2% FS or 2% relative
Sample pathway Color-coded Teflon® and PEEK® with automatic cleaning in all injection modes
Sample injection and sample handling Injection: sipper, rotary autosampler
Handling: automatic syringe with sliding TC furnace injector
Sample Injection Volume 10µL – 2.0 mL
IC pretreatment Available with optional autosampler
Reagent purge Yes
Reagents Required Hydrochloric acid, rinse water
Gas Supply Oxygen or Air, 99.995% (carbon dioxide and hydrocarbon free),
50-60 psig

 

General Instrument Specifications
Measurement Technique Solid-State, Non-Dispersive Infrared (SS-NDIR) detector
Operation Mode Controlled via PC software (Windows 7, 8, 10 PRO)
Operator Interface Windows®
Software (included) Multi-instrument control via PC-based software,
LIMS connectivity, data management, custom reports
Operating system requirements Windows® 7 (with Service Pack 1 or higher), Windows® 8, 8.1 & 10
Communications USB-to-RS422 communications cable (5m length)
Input and output relays Two user-programmable inputs, two user-programmable outputs
Ambient temperature range: 10 ˚C – 37 ˚C
Operating humidity: <90% noncondensing
Certifications CE; EMC: Directive 2014/30/EU; Safety: LVD 2014/35/EU;
RoHS: Directive 2011/65/EU
Power requirements 115/230V AC, 50/60 Hz, 750VA max
Benchspace with autosampler (optional) 14” W x 19”D (35.6cm W x 48.3 cm D)
Weight 17.5 kg (38.5 lbs), 37.5 kg (82.5 lbs) with autosampler option
Dimensions 29” H x 14” W x 19” D (74 cm H x 36 cm W x 48 cm D)
Warranty 12 months on parts and labor